PRODUCTS

Duplex Service Drop Wire

Duplex Service Drop Wire
-> Duplex Service Drop Wire Construction:
Concentric strand or compacted 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
 
-> Standards:
ASTM B-230, B-231, B-232 and B-399 & ICEA S-76-474
 
-> Application:
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction.
 
-> Duplex Service Drop Cable Property:
To be used at voltage of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLPE) insulated conductors.

-> Standards
B 230 Aluminum Wire1350-H 19 for Electrical Purpose
B 231 Aluminum Conductor, Concentric-lay-stranded
B 232 Aluminum Conductor, Concentric-lay-stranded, Coated Steel Reinforced (ACSR)
B 399 Concentric-lay-stranded 6201-T81 Aluminum Alloy Conductor
B 901 Compressed Round Stranded Aluminum Conductor Using Single Input Wire
Duplex Service Drop Cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

-> Duplex Service Drop technical parameter:

Code
Word
Phase Conductors Bare Natural Nominal Weight Ampacity Standard Package
Size &
Number
of wires
Insulation
Thickness
Nominal Diameter Size &
Number
of Wires
Rated
Strength
kg / km Coils Reels
Bare OD XLPE Aluminum Total
mm mm mm kg A m m
                         
AAC
Pekingese 6-Solid 1.14 4.1 6.4 6-7 255 20.8 72.9 94 78 305 1000
Collie 6-7 1.14 4.6 6.9 6-7 255 23.8 72.9 97 78 305 1000
Cocker 6-7 1.52 4.6 7.7 6-7 255 32.7 72.9 106 78 305 1000
Dachshund 4-Solid 1.14 5.2 7.5 6-7 400 26.8 114.6 141 103 305 500
Spaniel 4-7 1.14 5.9 8.2 6-7 400 29.8 116.1 146 103 305 500
Cairn 4-7 1.52 5.9 8.9 6-7 400 40.2 116.1 156 103 305 500
Doberman 2-7 1.14 7.4 9.7 2-7 612  38.7 184.5 223 136 152 500
Airedale 1-19 1.52 8.4 11.5 1-7 --- 56.5 233.6 290 158 152 500
Basset 1/0-7 1.52 9.3 12.4 1/0-7 903  64.0  294.7 359 182 152 457
Malemure 1/0-19 1.52 9.4 12.5 1/0-7 903  64.0  294.7 359 182 152 457
                         
AAAC
Chihuahua 6-Solid 1.14 4.1 6.4 6-7 499 20.8 72.9 94 78 305 1000
Vizsla 6-7 1.14 4.6 6.9 6-7 499 23.8 72.9 97 78 305 1000
Harrier 4-Solid 1.14 5.2 7.5 4-7 798 26.8 116.1 143 103 305 500
Whippet 4-7 1.14 5.9 8.2 4-7 798 29.8 116.1 146 103 305 500
Schnauzer 2-7 1.14 7.4 9.7 2-7 1,270  38.7 184.5 223 136 152 500
Afghan 1/0-7 1.52 9.3 12.4 1/0-7 2,023  64.0  296.1 360 182 152 457
heeler 1/0-19 1.52 9.4 12.5 1/0-7 2,023  64.0  296.1 360 182 152 457
                         
ACSR
Setter 6-Solid 1.14 4.1 6.4 6/6/01 540 20.8 72.9 94 78 305 1000
Shepherd 6-7 1.14 4.6 6.9 6/6/01 540 23.8 72.9 97 78 305 1000
Retriever 6-7 1.52 4.6 7.7 6/6/01 540 32.7 72.9 106 78 305 1000
Eskimo 4-Solid 1.14 5.2 7.5 4/6/01 844 26.8 114.6 141 103 305 500
Terrier 4-7 1.14 5.9 8.2 4/6/01 844 29.8 116.1 146 103 305 500
Yorkshire 4-7 1.52 5.9 8.9 4/6/01 844 40.2 116.1 156 103 305 500
Chow 2-7 1.14 7.4 9.7 2/6/01 1,293  38.7 184.5 223 136 152 500
Labrador 1-19 1.52 8.4 11.5 1/6/01 1,610  56.5 233.6 290 158 152 500
Bloodhound 1/0-7 1.52 9.3 12.4 1/0-6/1 1,987  64.0  294.7 359 182 152 457
Bull 1/0-19 1.52 9.4 12.5 1/0-6/1 1,987  64.0  294.7 359 182 152 457

previous:Duadruplex Service Drop Cable

next:Triplex Service Drop Cable

LEAVE YOUR DEMAND

HOT PRODUCTS

LV Aerial Bundled Cable
LV Aerial Bundled Cable

Applicable Standards: IEC60502, SANS1418 Rated Voltage: 0.6/1kV No. of Cores: 2, 3, 4 or 5 - Advantag

Triplex Service Drop Cable
Triplex Service Drop Cable

Concentric strand or compacted 1350-H19 conductor, polyethylene or crosslinked polyethylene insulatio

ACSR (Aluminium Conductors Steel Reinforced
ACSR (Aluminium Conductors Steel Reinforced

Aluminium Conductors Steel Reinforced are composed by bare concentric-lay-stranded aluminium wires wi

AAAC Bare Overhead Conductor
AAAC Bare Overhead Conductor

AAAC Bare Overhead Conductor (All Aluminium Alloy Conductor) is made of high strength Aluminium-Magne