HVDC Transformer

HVDC Transformer
HVDC transformers are key components of HVDC stations. HVDC converter and inverter stations terminate long-distance DC transmission lines or DC sea cables. This type of transformer provides the interface between AC grids and high power rectifiers and are used to control the load flow over the DC transmission lines. These actors adapt the AC grid voltage to an adequate level which is suitable for feeding the valve system of DC converter and inverter.
 
Design options:
The design concept of HVDC transformers is mainly influenced by the rated voltage, rated power and transportation requirements like dimensions, weight and mode of transportation.
 
Many large power HVDC converter station are located in rural areas of low infrastructure. Frequently, special geometrical profiles have to be fulfilled in order to move such transformers by railway.
 
Typically, HVDC transformers are single phase units containing 2 winding limbs. This concept can include either 2 parallel valve windings (two for delta or two for wye system, fig. 5.8-1) or two different valve windings. In order to reduce the total transportation height frequently the core assembly includes 2 return limbs. Due to redundancy requirements in HVDC stations 3 phase units are quite uncommon.
The valve windings are exposed to AC and DC dielectric stress and therefore a special insulation assembly is necessary. Furthermore, special lead systems connecting the turrets and windings have to be installed in order to withstand the DC voltage of rectifier. Additionally, the load current contains harmonic components of considerable energy resulting in higher losses and increased noise. Above all, special bushings are necessary for the valve side to access upper and lower winding terminals of each system from outside. Conclusively, two identical bushings are installed for star or delta system.
 
For approving the proper design and quality of manufacturing special applied DC and DC polarity reversal tests have to be carried out. The test bay has to be equipped with DC test apparatus accordingly and needs to provide adequate geometry to withstand the DC test voltage.

previous:none

next:Phase-Shifting Transformer

LEAVE YOUR DEMAND

HOT PRODUCTS

LV Aerial Bundled Cable
LV Aerial Bundled Cable

Applicable Standards: IEC60502, SANS1418 Rated Voltage: 0.6/1kV No. of Cores: 2, 3, 4 or 5 - Advantag

Triplex Service Drop Cable
Triplex Service Drop Cable

Concentric strand or compacted 1350-H19 conductor, polyethylene or crosslinked polyethylene insulatio

ACSR (Aluminium Conductors Steel Reinforced
ACSR (Aluminium Conductors Steel Reinforced

Aluminium Conductors Steel Reinforced are composed by bare concentric-lay-stranded aluminium wires wi

AAAC Bare Overhead Conductor
AAAC Bare Overhead Conductor

AAAC Bare Overhead Conductor (All Aluminium Alloy Conductor) is made of high strength Aluminium-Magne